ADACON UK

    How Long Do Modular Buildings Last?

    A properly specified modular building on a sound, level base is a permanent structure, not a temporary one. Lifespan is driven by the chassis and frame protection, the quality of the base, how well the roof and module joints are maintained, and the internal environment — particularly in wet areas.

    Adacon Technical Team · Published

    What determines lifespan

    • Galvanised steel chassis and frame protection against corrosion
    • A level, well-drained base that keeps standing water away from the underside
    • Roof and joint sealing, particularly on multi-module buildings
    • Ventilation and extraction in kitchens, WCs and shower rooms
    • External finish maintenance appropriate to the cladding chosen

    Sensible maintenance

    Clear gutters and roof drainage, inspect the joints between modules annually, keep vegetation and soil away from the chassis, and keep extraction working in wet rooms. That short list prevents most of the problems that shorten the life of any modular building.

    Relocation

    Because modules are lifted into place rather than built in place, a modular building can be moved to another site later, subject to access and craneage — an option a traditional building does not offer.

    Where to go next

    P300–P700 range, or bespoke

    P200 unit
    1.9m × 2.2m externally; approximately 1.7m × 2.0m usable internally (3.4 m² usable internal area per separate unit)
    P300 unit
    2.9m × 2.2m externally; approximately 2.7m × 2.0m usable internally (5.4 m² usable internal area per separate unit)
    P400 unit
    3.9m × 2.2m externally; approximately 3.7m × 2.0m usable internally (7.4 m² usable internal area per separate unit)
    P500 unit
    4.9m × 2.2m externally; approximately 4.7m × 2.0m usable internally (9.4 m² usable internal area per separate unit)
    P600 unit
    5.9m × 2.2m externally; approximately 5.7m × 2.0m usable internally (11.4 m² usable internal area per separate unit)
    P700 unit
    6.9m × 2.2m externally; approximately 6.7m × 2.0m usable internally (13.4 m² usable internal area per separate unit)
    Configuration
    Mix P200, P300, P400, P500, P600 and P700 units to create tailored footprints and shapes
    Bespoke
    Bespoke sizes considered to suit your brief — contact us
    Joined internal space
    Open joins remove the adjoining shell walls and can increase usable space. Final clear area depends on layout and partitions.
    Unit height
    2.40m external / 2.16m internal
    Storeys
    Up to two storeys, subject to final project design
    Delivery
    UK mainland and Northern Ireland — transport quoted separately

    Adacon modular buildings use P200, P300, P400, P500, P600 and P700 units with external lengths of 1.9m, 2.9m, 3.9m, 4.9m, 5.9m and 6.9m, a common 2.2m width and 2.40m external / 2.16m internal height. The sizes can be combined to create more tailored floor areas and building shapes, joined side by side or stacked to two storeys subject to the final project design.

    Design your modular building online

    Set the layout, windows, doors and fit-out and see a live estimate as you go.

    Design Your Modular Building

    More guides

    Get a price for Modular Buildings

    Tell us what you need and we'll come back with pricing and lead times — usually within one working day.

    So we can call you back about your enquiry

    Enquiring about: Modular Buildings

    No obligation. We reply within one working day.