Modular Healthcare Buildings
Healthcare buildings are planned as a route: patients arrive at reception and waiting, move into a consultation or treatment room, and staff, records and clinical waste travel separately. Our modules are configured around that route, so you decide how many clinical rooms you need, where reception sits, and how staff and accessible facilities are kept off the patient path.

Get a price for healthcare buildings
Tell us what you need and we'll come back with pricing and lead times — usually within one working day.
Hire Healthcare Buildings in the UK
Need healthcare buildings for a fixed period? Hire it instead of buying. Adacon manufactures the building to your layout and hands it over on hire terms, then collects it when you no longer need it — with the same quality, fit-out and design freedom as a purchase.
Hire terms are flexible — tell us how long you need the unit and we will confirm the rate for that period.
Get a hire price for healthcare buildings
Tell us when you need it and for how long. We reply with hire terms — and a purchase price too if you tick compare.
Planned room by room around the patient route
We set the entrance, reception and waiting area first, then the clinical rooms behind a controlled door, with staff space and storage kept separate. Door widths, drainage, hand-wash positions, ventilation paths and power runs are planned around the equipment you intend to install rather than a standard cabin layout.
- Reception, waiting and accessible entrance separated from clinical rooms
- GP, consultation or treatment rooms sized around couch, desk and equipment
- Clinical hand-wash basins, wipe-clean sealed finishes and drainage runs
- Diagnostic, phlebotomy or minor-procedure room where required
- Accessible patient WC and separate staff WC
- Staff room, office and secure records and consumables storage
- Ventilation, heating and dedicated power circuits for clinical equipment
- Extension alongside an existing practice, or temporary decant space during a refit
Example configurations
Buildings combine P300, P400, P500, P600 and P700 units, with bespoke options. A separate P600 provides approximately 11.4 m² usable internally. Example areas use a conservative per-module allowance before partitions; open joins can provide more space. Units can be combined or stacked over two storeys.
Branch clinic or added consulting space: waiting corner, one clinical room and an accessible WC.
Reception and waiting, two clinical rooms, staff room, office and accessible WC.
Multi-room clinic or community health facility with diagnostics, admin and a separate staff wing, on one level or two storeys.
Healthcare Buildings — key facts
- P300 unit
- 2.9m × 2.2m externally; approximately 2.7m × 2.0m usable internally (5.4 m² usable internal area per separate unit)
- P400 unit
- 3.9m × 2.2m externally; approximately 3.7m × 2.0m usable internally (7.4 m² usable internal area per separate unit)
- P500 unit
- 4.9m × 2.2m externally; approximately 4.7m × 2.0m usable internally (9.4 m² usable internal area per separate unit)
- P600 unit
- 5.9m × 2.2m externally; approximately 5.7m × 2.0m usable internally (11.4 m² usable internal area per separate unit)
- P700 unit
- 6.9m × 2.2m externally; approximately 6.7m × 2.0m usable internally (13.4 m² usable internal area per separate unit)
- Configuration
- Mix P300, P400, P500, P600 and P700 units to create tailored footprints and shapes
- Bespoke
- Bespoke sizes considered to suit your brief — contact us
- Joined internal space
- Open joins remove the adjoining shell walls and can increase usable space. Final clear area depends on layout and partitions.
- Unit height
- 2.40m external / 2.16m internal
- Storeys
- Up to two storeys, subject to final project design
- Delivery
- UK mainland and Northern Ireland — transport quoted separately
Adacon modular buildings use P300, P400, P500, P600 and P700 units with external lengths of 2.9m, 3.9m, 4.9m, 5.9m and 6.9m, a common 2.2m width and 2.40m external / 2.16m internal height. The sizes can be combined to create more tailored floor areas and building shapes, joined side by side or stacked to two storeys subject to the final project design.
What's available for a healthcare building
A standard module is not automatically a compliant clinical facility. Specialist requirements — infection-control and ventilation design, medical gases, radiation protection, CQC or health-board standards and clinical equipment specification — are confirmed project by project with your own clinical, regulatory and equipment advisers. We build the layout, shell and services to the specification agreed for your project. Dental and veterinary work has its own dedicated pages.
Healthcare Buildings — photo gallery



Design your healthcare building
Set the clinical rooms, waiting area and staff space and get an estimated price.
Healthcare Buildings — common questions
Related uses
Configurable modular laboratory buildings for education, research, healthcare and commercial testing. Building shell and agreed fit-out; specialist services confirmed per project.
Modular dental practice buildings configured around reception and waiting, surgeries, decontamination, accessible WC and staff space. New practices, extensions and temporary decant space.
Modular veterinary clinic buildings configured around reception, consultation, prep, theatre and recovery. New practices, branch surgeries and extensions to existing sites.
Modular office buildings from a single room to multi-module, two-storey layouts. Fitted out, insulated and delivered UK-wide. Configure yours online.
Design options for this build
All design optionsLiving in one of these?
All modular homesUseful guides
Practical guidance on module sizes, configuration, fit-out and the factors that shape a tailored modular-building quotation.
Whether a modular building needs planning permission depends on its use, size, siting and duration. Read how the common cases usually work in the UK.
Modular buildings need a level, load-bearing base rather than traditional deep foundations. Learn what base types suit garden rooms, site offices and two-storey builds.
Built from five unit sizes, or bespoke
Every Adacon building is made from these units, or built to a bespoke size. Units can be combined — joined end to end, side by side, or stacked to two storeys — to create larger buildings.
| Unit | External footprint | Approximate usable internal area |
|---|---|---|
| P300 | 2.9m × 2.2m | 2.7m × 2.0m (≈5.4 m²) |
| P400 | 3.9m × 2.2m | 3.7m × 2.0m (≈7.4 m²) |
| P500 | 4.9m × 2.2m | 4.7m × 2.0m (≈9.4 m²) |
| P600 | 5.9m × 2.2m | 5.7m × 2.0m (≈11.4 m²) |
| P700 | 6.9m × 2.2m | 6.7m × 2.0m (≈13.4 m²) |
| Bespoke | Built to your size | Contact us |