Modular Changing Places Toilets
A Changing Places toilet is not an accessible WC. It is a larger room for people who cannot use a standard accessible toilet, with a hoist, an adult-sized changing bench and space for up to two carers. Adacon builds the modular building around that room, and the specialist equipment is specified and installed with an accessibility-equipment partner, so the facility arrives as one coordinated project for your site.

Get a price for changing places toilets
Tell us where it needs to go, who will use it and whether you're applying for funding. Upload your site plan or photographs and we'll assess the building requirement.
Hire Changing Places Toilets in the UK
Need changing places toilets for a fixed period? Hire it instead of buying. Adacon manufactures the building to your layout and hands it over on hire terms, then collects it when you no longer need it — with the same quality, fit-out and design freedom as a purchase.
Hire terms are flexible — tell us how long you need the unit and we will confirm the rate for that period.
Get a hire price for changing places toilets
Tell us when you need it and for how long. We reply with hire terms — and a purchase price too if you tick compare.
Were you originally considering hiring?
We can compare the purchase price against your expected hire period.
Changing Places toilet vs accessible WC
An accessible (Document M) WC is designed for independent wheelchair users. A Changing Places facility serves people with profound and multiple learning disabilities and other conditions who need assistance and equipment to use the toilet. Current UK guidance describes a typical minimum of 12 m² clear internal space, normally around 3m × 4m, with a greater ceiling height to suit the hoist.
- Ceiling-track hoist covering the WC, bench and basin
- Height-adjustable, adult-sized changing bench
- Centrally positioned (peninsular) WC with space on both sides
- Height-adjustable or accessible wash basin
- Clear space for the user and up to two carers
- Privacy screen, waste disposal and non-slip flooring
Designed around the specification and the equipment first
We plan the room against the current Changing Places specification and the chosen equipment package before the building is sized, then join modules to give the clear internal space, ceiling height and door openings the room needs. The building, fit-out and specialist equipment are coordinated as one project.
- Clear internal room sized to the current specification, typically from 12 m²
- Structure and ceiling planned for a ceiling-track hoist
- Wide, level-access entrance and suitable door opening
- Heating, ventilation, lighting and hot water provision
- Optional standard accessible WCs or baby change in the same building
- Specialist equipment specified and installed with an accessibility partner
- Formal quotation, layout and drawings to support funding applications
Example configurations
Buildings combine P300, P400, P500, P600 and P700 units, with bespoke options. A separate P600 provides approximately 11.4 m² usable internally. Example areas use a conservative per-module allowance before partitions; open joins can provide more space. Units can be combined or stacked over two storeys.
A single Changing Places room as its own building, sized from the equipment layout.
Changing Places room plus standard accessible WCs, baby change or a plant/store room.
Included within a clubhouse, changing-room, café or SEND building.
Changing Places Toilets — key facts
- P200 unit
- 1.9m × 2.2m externally; approximately 1.7m × 2.0m usable internally (3.4 m² usable internal area per separate unit)
- P300 unit
- 2.9m × 2.2m externally; approximately 2.7m × 2.0m usable internally (5.4 m² usable internal area per separate unit)
- P400 unit
- 3.9m × 2.2m externally; approximately 3.7m × 2.0m usable internally (7.4 m² usable internal area per separate unit)
- P500 unit
- 4.9m × 2.2m externally; approximately 4.7m × 2.0m usable internally (9.4 m² usable internal area per separate unit)
- P600 unit
- 5.9m × 2.2m externally; approximately 5.7m × 2.0m usable internally (11.4 m² usable internal area per separate unit)
- P700 unit
- 6.9m × 2.2m externally; approximately 6.7m × 2.0m usable internally (13.4 m² usable internal area per separate unit)
- Configuration
- Mix P200, P300, P400, P500, P600 and P700 units to create tailored footprints and shapes
- Bespoke
- Bespoke sizes considered to suit your brief — contact us
- Joined internal space
- Open joins remove the adjoining shell walls and can increase usable space. Final clear area depends on layout and partitions.
- Unit height
- 2.40m external / 2.16m internal
- Storeys
- Up to two storeys, subject to final project design
- Delivery
- UK mainland and Northern Ireland — transport quoted separately
Adacon modular buildings use P200, P300, P400, P500, P600 and P700 units with external lengths of 1.9m, 2.9m, 3.9m, 4.9m, 5.9m and 6.9m, a common 2.2m width and 2.40m external / 2.16m internal height. The sizes can be combined to create more tailored floor areas and building shapes, joined side by side or stacked to two storeys subject to the final project design.
What's available for a changing places toilet
Adacon does not currently claim that a building is a certified or compliant Changing Places facility. Each project is designed against the current specification with a specialist equipment partner, and compliance, registration and building-regulation approval are confirmed per project.
Changing Places Toilets — photo gallery








Need a Changing Places facility?
Tell us where it needs to go, who will use it and whether you're applying for funding.
Changing Places Toilets — common questions
Related uses
Pre-built toilet blocks for sale, designed around your site. Campsites, sports grounds, construction sites and events. Request a price and layout.
Modular SEND, SEN and SEMH classrooms for schools adding specialist provision — teaching rooms, intervention and sensory spaces, accessible washrooms and staff areas.
Modular changing rooms for sports clubs, staff facilities and leisure sites. Benches, lockers, showers and wet/dry zoning. Configure yours online.
Design options for this build
All design optionsLiving in one of these?
All modular homesUseful guides
Yes. P600 modules can be configured with WCs, showers, wash areas, partitions and the associated plumbing — as part of a building or as a standalone sanitary block.
Practical guidance on module sizes, configuration, fit-out and the factors that shape a tailored modular-building quotation.
Whether a modular building needs planning permission depends on its use, size, siting and duration. Read how the common cases usually work in the UK.
Built from five unit sizes, or bespoke
Every Adacon building is made from these units, or built to a bespoke size. Units can be combined — joined end to end, side by side, or stacked to two storeys — to create larger buildings.
| Unit | External footprint | Approximate usable internal area |
|---|---|---|
| P200 | 1.9m × 2.2m | 1.7m × 2.0m (≈3.4 m²) |
| P300 | 2.9m × 2.2m | 2.7m × 2.0m (≈5.4 m²) |
| P400 | 3.9m × 2.2m | 3.7m × 2.0m (≈7.4 m²) |
| P500 | 4.9m × 2.2m | 4.7m × 2.0m (≈9.4 m²) |
| P600 | 5.9m × 2.2m | 5.7m × 2.0m (≈11.4 m²) |
| P700 | 6.9m × 2.2m | 6.7m × 2.0m (≈13.4 m²) |
| Bespoke | Built to your size | Contact us |