ADACON UK
    Two single-storey dark grey modules with a glazed door and large windows, Adacon P600 modular building
    Two-module P600 security cabin with WC for access control at sites, car parks and distribution centres.

    Security Cabins

    Two-Module Security Cabin with WC

    This single-storey security cabin combines two P600 modules in an 11.8m-long run, providing approximately 24 m² of internal floor area with an integrated WC. It suits sites, car parks and distribution centres that need a practical base for controlling vehicle, visitor and personnel access.

    £21,500ex VAT

    £25,800 inc VAT · standard fitted specification. Delivery, groundworks and site-specific works quoted separately.

    Modules
    2
    Storeys
    1
    Floor area
    24 m²
    Footprint
    11.8m x 2.2m footprint

    What's included

    • Two linked P600 modules in a single-storey run
    • 11.8m x 2.2m overall footprint
    • Approximately 24 m² internal floor area
    • Single glazed entrance door
    • Eight large or full-size windows
    • Smooth Dark grey exterior cladding
    • Full internal fit-out with WC

    A clear, linear layout for site control

    This configuration uses two 5.9m x 2.2m P600 modules linked end to end in a single-storey run. The completed building has an overall footprint of 11.8m x 2.2m and provides approximately 24 m² of internal floor area. Its long, narrow form is well suited to entrance lanes, perimeter positions and other locations where security staff need broad external visibility without taking up unnecessary site space. Further examples are available on the security cabins page.

    Module 1 layout

    Module 1 forms the western half of the building. Its exposed north-facing 5.9m wall contains two large windows, giving staff a wide view along that side of the cabin. The south-facing wall has one single glazed entrance door, providing direct access into the building. A full-size window is fitted in the exposed 2.2m western end wall, extending visibility towards approaching traffic, pedestrians or a controlled entrance point.

    Module 2 layout

    Module 2 continues the run to the east. Two large windows are fitted along its north-facing 5.9m wall, maintaining the extended sightline created by Module 1. The south-facing wall also has two large windows, providing observation in the opposite direction. At the exposed eastern end, a full-size window gives a clear outward view from the end of the building. Together, the two modules provide four large windows on the north elevation, two on the south elevation and one full-size window at each end.

    Entrance, exterior and roof finish

    The single glazed door is positioned on the south wall of Module 1. This arrangement keeps access concentrated at one end of the working space while leaving the remaining exposed walls available for windows. The exterior is finished in smooth Dark grey cladding. A flat roof with a slim fascia gives the cabin a restrained, modern profile suitable for operational sites, managed car parks and distribution-centre entrances.

    Internal fit-out

    The building is supplied to Adacon’s full fit-out standard and this configuration includes a WC. The internal space can support security and site-control duties such as monitoring arrivals, checking documentation and managing access. Buyers requiring a different P600 arrangement can review options through the P600 configurator.

    Price and scope

    The indicative price is £21,500 excluding VAT, or £25,800 including VAT, for the standard fitted specification described here. This covers the two-module, single-storey building with the stated Dark grey exterior, flat roof, glazed entrance door, specified window arrangement and WC fit-out.

    • Delivery is quoted separately.
    • Groundworks are quoted separately.
    • Site-specific works are quoted separately.

    Typical lead time

    A typical lead time is 8–12 weeks. The programme is confirmed for each order and may depend on the final specification, site information, delivery arrangements and installation requirements. Delivery and installation planning should be agreed early, particularly where access must be coordinated around live traffic routes or security operations.

    Siting requirements

    The cabin requires a suitable prepared and level base, together with clear access for delivery and installation. The available route must be assessed for vehicle access, unloading space, overhead restrictions and safe working areas. Required service connections for the WC must also be identified before installation. Ground conditions, drainage, utility routes and any other site-specific requirements should be established during the site review and allowed for in the separate quotation.

    Full specification

    2 P600 modules (single storey), run layout, 11.8m x 2.2m footprint, approx 24 m2 internal floor area.
    Exterior: smooth cladding in Dark grey. Roof: flat roof with slim fascia.
    Module 1 (ground floor) exposed walls — north (5.9m side): Large window + Large window; south (5.9m side): Glazed door (single); west (2.2m end): Full-size window.
    Module 2 (ground floor) exposed walls — north (5.9m side): Large window + Large window; east (2.2m end): Full-size window; south (5.9m side): Large window + Large window.
    Internal fit-out includes: WC.

    Frequently asked questions

    Make it yours

    Change the module count, layout, windows, doors and finish — then get an instant estimate.

    Get a price for Two-Module Security Cabin with WC

    Tell us what you need and we'll come back with pricing and lead times — usually within one working day.

    Enquiring about: Two-Module Security Cabin with WC

    No obligation. We reply within one working day.