ADACON UK
    Anthracite-clad modular gatehouse beside a controlled site entrance
    Two-module P600 gatehouse configured for security and site control.

    Gatehouses

    Two-Module P600 Gatehouse with WC

    This single-storey P600 gatehouse combines two steel-framed modules in an 11.8m-long run layout, with a WC requested for the final plan. It suits security and site control at logistics parks, schools and gated developments.

    £27,800ex VAT

    £33,360 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.

    Made to order. Build and delivery timing will be confirmed with your quotation.

    Call about this item
    PLACE ORDER

    Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.

    Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.

    Change the layout in the configurator
    Modules
    2
    Storeys
    1
    Approx. usable internal area
    22.8 m² before partitions
    External dimensions
    11.8m x 2.2m footprint

    Design highlights

    • Two P600 modules in a single-storey run layout
    • 11.8m x 2.2m external footprint
    • Approximately 22.8m² usable internal area before partitions
    • Anthracite ARLINE AR16016 vertical grooved plank cladding
    • Glazed single entrance door with windows across both modules
    • Full-size window at each exposed end
    • WC requested for confirmation in the final layout

    Configuration and dimensions

    This gatehouse uses two P600 modules connected in a single-storey run layout. Together, they create an external footprint of 11.8m x 2.2m and provide approximately 22.8m² of usable internal area before partitions. This figure uses a conservative per-module allowance; a connected open layout may provide more usable space depending on the final arrangement.

    Each steel-framed module measures 5.9m x 2.2m and is 2.40m high externally. Its approximate usable interior is 5.7m x 2.0m, with a 2.16m internal ceiling. The linear format is suited to a gatehouse where clear visibility and a practical working area support access monitoring and day-to-day site control.

    Windows and entrance

    The stored arrangement places two large windows on the north wall of Module 1. Its south wall has a single glazed door positioned between two small windows, while the exposed west end has a full-size window.

    Module 2 also has two large windows on its north wall. Its south wall has a further two large windows, and the exposed east end has a full-size window. This specification creates glazing across both long elevations and at each exposed end of the connected run. The final relationship between the open working area, circulation space and requested WC is confirmed during layout development.

    Anthracite external finish

    All exposed outside walls are specified with Anthracite ARLINE AR16016 grooved plank cladding applied between the frame. The boards run vertically across the north, south and west walls of Module 1 and the north, south and east walls of Module 2. The connected ends are not exposed external walls in this run configuration.

    Above, the building has a flat roof with an approximately 120mm steel-frame fascia. No additional fascia has been selected. Final fixture, finish and detailing choices are confirmed by quotation rather than assumed from illustrations.

    Requested WC and internal finishes

    A WC has been requested, but its exact position and room arrangement remain subject to confirmation in the final layout. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels available as an option. If a shower room is selected during final planning, wet-room PVC flooring is used within that room.

    Plaster applies to the outside faces of bathroom walls when that finish is selected. Elsewhere, insulated sandwich panels are the included internal wall finish. Any alternative wall treatments, flooring or room-specific finishes must be chosen to suit the confirmed plan and recorded in the quotation.

    Estimate, transport and siting

    The indicative configured estimate is £27,800 excluding VAT, or £33,360 including VAT, subject to quotation. Transport is priced separately according to the destination postcode and site access. Offloading or cranage, groundworks and other site-specific works are also separate and are not included in the indicative estimate.

    Placement, access, levels and servicing requirements must be assessed for the intended site. Final siting is subject to survey, with the necessary groundworks and site provisions established for the location. The stored configuration can be reviewed in the P600 configurator before the final layout, finishes and quotation are confirmed.

    Full specification

    2 P600 modules (single storey), run layout, 11.8m x 2.2m footprint, approx 22.8 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m.
    Exterior: ARLINE AR16016 grooved plank applied to exposed walls between the frame in Anthracite. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia).
    Selected outside walls: Module 1 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards. Cladding prices are quote-only and must not be itemised in public copy.
    Module 1 P600 (ground floor) exposed walls — north (5.9m side): Large window + Large window; south (5.9m side): Small window + Glazed door (single) + Small window; west (2.2m end): Full-size window.
    Module 2 P600 (ground floor) exposed walls — north (5.9m side): Large window + Large window; east (2.2m end): Full-size window; south (5.9m side): Large window + Large window.
    Requested fit-out to confirm in the final layout: WC. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.

    Frequently asked questions

    Make it yours

    Change the module count, layout, windows, doors and finish — then get an instant estimate.

    Get a price for Two-Module P600 Gatehouse with WC

    Tell us what you need and we'll come back with pricing and lead times — usually within one working day.

    So we can call you back about your enquiry

    Enquiring about: Two-Module P600 Gatehouse with WC