
Security Cabins
Single-Module Security Cabin with WC Provision
This single-storey P600 security cabin uses one 5.9m x 2.2m module with access-control openings and a requested WC fit-out. It suits sites, car parks and distribution centres where personnel need a dedicated position for controlling entry and exit.
£14,100ex VAT
£16,920 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.
Made to order. Build and delivery timing will be confirmed with your quotation.
Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.
Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.
- Modules
- 1
- Storeys
- 1
- Approx. usable internal area
- 11.4 m² before partitions
- External dimensions
- 5.9m x 2.2m footprint
Design highlights
- One P600 module in a single-storey run layout
- 5.9m x 2.2m external footprint
- Approximately 11.4m2 usable internal area before partitions
- Sliding drive-through serving window
- Single glazed entrance door and four windows
- Anthracite ARLINE AR14514 fine-ribbed wall cladding
- Requested WC fit-out subject to final layout confirmation
Single-module run layout
This security cabin is configured as one steel-framed P600 module in a single-storey run layout. Its external footprint is 5.9m x 2.2m, providing approximately 11.4m2 of usable internal area before partitions, based on a conservative per-module allowance. The approximate usable interior is 5.7m x 2.0m. The module stands 2.40m externally and has a 2.16m internal ceiling.
The compact format is intended for access control without creating a larger linked building. It provides a practical base for security personnel monitoring vehicles, visitors and site movements. Typical settings include industrial sites, controlled car parks and distribution centres. Further information about this application is available under security cabins.
Windows, door and serving opening
The north-facing 5.9m wall includes a sliding drive-through serving window, allowing staff to communicate with drivers and handle access-related interactions from inside the cabin. The east 2.2m end wall has a full-size window. On the south-facing 5.9m wall, the stored arrangement comprises a small window, a single glazed door and a second small window. The west 2.2m end wall includes another full-size window.
These openings are specific to this configuration and distribute visibility across all four elevations. Their relationship to internal furniture, equipment and the requested WC must be confirmed through the final room layout. Illustrated fixtures, finishes and internal arrangements are indicative until recorded in the quotation.
Anthracite exterior and flat roof
All four outside walls are selected with Anthracite ARLINE AR14514 fine-ribbed cladding, applied vertically to the exposed wall areas between the frame. This full-wall cladding selection covers the north and south long sides together with the east and west end walls. Cladding is included within the configured estimate but is not separately itemised in public pricing.
The building has a flat roof with an approximately 120mm steel-frame fascia. No additional fascia is selected. The restrained Anthracite exterior gives the cabin a consistent appearance suited to operational entrances and controlled site environments.
Requested WC and internal finishes
A WC has been requested for this configuration, with its final position and effect on the usable internal area to be confirmed in the completed layout. Bathroom walls use 40mm waterproof insulated sandwich panels as standard. Hygienic panels are available as an optional bathroom finish. Where selected, plaster applies outside the bathroom walls.
Elsewhere, insulated sandwich panels are the included internal wall finish. Any alternative finishes are selected to suit the final room arrangement and confirmed by quotation. No general flooring finish has been specified for this stored design. Wet-room PVC flooring applies to shower rooms, but a shower room is not included in this configuration.
Estimate and site requirements
The indicative configured estimate is £14,100 excluding VAT, or £16,920 including VAT, subject to quotation and confirmation through the final configuration. Transport is priced separately according to postcode and site access. Offloading or cranage, groundworks and other site-specific works are also separate. Siting requirements remain subject to survey, including access, ground conditions and the practical needs of placing the module at the intended control point.
Full specification
1 P600 module (single storey), run layout, 5.9m x 2.2m footprint, approx 11.4 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m. Exterior: ARLINE AR14514 fine-ribbed applied to exposed walls between the frame in Anthracite. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia). Selected outside walls: Module 1 North wall: Full-wall cladding, Anthracite, ARLINE AR14514 fine-ribbed, vertical boards; Module 1 East wall: Full-wall cladding, Anthracite, ARLINE AR14514 fine-ribbed, vertical boards; Module 1 South wall: Full-wall cladding, Anthracite, ARLINE AR14514 fine-ribbed, vertical boards; Module 1 West wall: Full-wall cladding, Anthracite, ARLINE AR14514 fine-ribbed, vertical boards. Cladding prices are quote-only and must not be itemised in public copy. Module 1 P600 (ground floor) exposed walls — north (5.9m side): Drive-through serving window (sliding); east (2.2m end): Full-size window; south (5.9m side): Small window + Glazed door (single) + Small window; west (2.2m end): Full-size window. Requested fit-out to confirm in the final layout: WC. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.
Frequently asked questions
Make it yours
Change the module count, layout, windows, doors and finish — then get an instant estimate.
Get a price for Single-Module Security Cabin with WC Provision
Tell us what you need and we'll come back with pricing and lead times — usually within one working day.