ADACON UK
    P600 security cabin positioned at a controlled site entrance
    Single-module P600 security cabin configured for access control at sites, car parks and distribution centres.

    Security Cabins

    Single-Module P600 Security Cabin with Requested WC

    This single-storey P600 security cabin uses one 5.9m x 2.2m module, with a requested WC to be confirmed in the final layout. It suits sites, car parks and distribution centres that need a dedicated point for access control and site supervision.

    £12,900ex VAT

    £15,480 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.

    Made to order. Build and delivery timing will be confirmed with your quotation.

    Call about this item
    PLACE ORDER

    Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.

    Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.

    Change the layout in the configurator
    Modules
    1
    Storeys
    1
    Approx. usable internal area
    11.4 m² before partitions
    External dimensions
    5.9m x 2.2m footprint

    Design highlights

    • One P600 module in a single-storey run layout
    • 5.9m x 2.2m external footprint
    • Approximately 11.4 m2 usable internal area before partitions
    • Two large, two full-size and two small windows
    • Single glazed external door
    • Light Grey RAL 7035 smooth insulated exterior panels
    • Requested WC subject to final layout confirmation

    Single-module run layout

    This configuration uses one P600 module arranged as a single-storey run layout, with no linked or stacked modules. Its external footprint is 5.9m x 2.2m, and the module is 2.40m high externally. Inside, the approximate usable dimensions are 5.7m x 2.0m, with a 2.16m ceiling. The configuration provides approximately 11.4 m2 of usable internal area before partitions, based on a conservative per-module allowance.

    Windows, entrance and external finish

    The north-facing 5.9m wall has two large windows. The opposite south-facing wall has a single glazed door positioned with one small window on either side. Each 2.2m end wall—the east and west elevations—has one full-size window. This arrangement gives the cabin openings on every elevation while retaining a single external entrance.

    All four outside walls use the selected standard insulated sandwich panels in Light Grey, RAL 7035, with a smooth finish. The panels are installed vertically as the included external treatment. Above them is a flat roof with an approximately 120mm steel-frame fascia; no additional fascia has been selected. Cladding costs are confirmed within the overall quotation rather than itemised publicly.

    Requested WC and internal finishes

    A WC has been requested for this security cabin, but its position, enclosure and effect on the open internal space remain subject to confirmation in the final room layout. Bathroom walls use 40mm waterproof insulated sandwich panels as standard. Hygienic bathroom panels are available as an optional selection. Where plaster is selected, it applies outside the bathroom walls rather than replacing the specified bathroom panel system.

    Elsewhere, insulated sandwich panels are the included internal wall finish. Any alternative finishes are selected and confirmed against the final room arrangement. Wet-room PVC flooring applies to shower rooms, but no shower room forms part of this stored configuration. No other precise internal flooring or decorative finish has been specified in the brief.

    Security and site-control use

    Designed as a security cabin, this configuration is suited to sites, car parks and distribution centres where personnel control entry, monitor movements or supervise a defined access point. The multiple windows support outward visibility, while the requested WC is intended to provide a practical staff facility once its layout has been agreed.

    The indicative configured estimate is £12,900 ex VAT, or £15,480 inc VAT, subject to quotation. The stored arrangement can be reviewed through the building configurator, but the quotation will confirm the final layout, fixtures, finishes and commercial scope. Illustrated details should not be treated as guaranteed unless they are expressly included in that quotation.

    Siting and separate site costs

    Final siting is subject to a site survey and confirmation of access, levels and local conditions. Transport is priced separately according to postcode and access requirements. Offloading or cranage, groundworks and any site-specific works are also separate from the indicative configured estimate. The receiving site must therefore be assessed before transport and placement requirements can be finalised.

    Full specification

    1 P600 module (single storey), run layout, 5.9m x 2.2m footprint, approx 11.4 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m.
    Exterior: included vertical insulated sandwich panels in Light Grey (RAL 7035). Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia).
    Selected outside walls: Module 1 North wall: Standard insulated panel, Light Grey (RAL 7035), Smooth; Module 1 East wall: Standard insulated panel, Light Grey (RAL 7035), Smooth; Module 1 South wall: Standard insulated panel, Light Grey (RAL 7035), Smooth; Module 1 West wall: Standard insulated panel, Light Grey (RAL 7035), Smooth. Cladding prices are quote-only and must not be itemised in public copy.
    Module 1 P600 (ground floor) exposed walls — north (5.9m side): Large window + Large window; east (2.2m end): Full-size window; south (5.9m side): Small window + Glazed door (single) + Small window; west (2.2m end): Full-size window.
    Requested fit-out to confirm in the final layout: WC. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.

    Frequently asked questions

    Make it yours

    Change the module count, layout, windows, doors and finish — then get an instant estimate.

    Get a price for Single-Module P600 Security Cabin with Requested WC

    Tell us what you need and we'll come back with pricing and lead times — usually within one working day.

    So we can call you back about your enquiry

    Enquiring about: Single-Module P600 Security Cabin with Requested WC

    No obligation. We reply within one working day.