
Modular Changing Rooms
8-Module Single-Storey Changing Rooms with WC and Shower
This single-storey modular changing room configuration combines eight P600 modules in a 17.7m x 6.6m grid layout, with a WC and shower requested for the final plan. It is designed for football, rugby and cricket clubs seeking approximately 91.2m² of usable internal area before partitions.
£106,800ex VAT
£128,160 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.
Made to order. Build and delivery timing will be confirmed with your quotation.
Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.
Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.
- Modules
- 8
- Storeys
- 1
- Approx. usable internal area
- 91.2 m² before partitions
- External dimensions
- 17.7m x 6.6m footprint
Design highlights
- Eight P600 modules arranged over a single storey
- 17.7m x 6.6m external footprint
- Approximately 91.2m² usable internal area before partitions
- Anthracite ARLINE AR16016 vertical grooved plank cladding
- Single glazed entrance door with small flanking windows
- High-level, top-only windows across selected exposed walls
- WC and shower requested for the final room layout
Eight-module grid configuration
This modular changing room is configured from eight steel-framed P600 modules arranged over one storey in a grid layout. Each module measures 5.9m x 2.2m externally, giving the complete building an external footprint of 17.7m x 6.6m. The approximate usable internal area is 91.2m² before partitions, based on a conservative allowance of 5.7m x 2.0m per module. Connected open layouts may provide more usable space, depending on the final partition plan.
Each module is 2.40m high externally and has a 2.16m internal ceiling. The configuration is intended for the Sport & Leisure sector, particularly football, rugby and cricket clubs requiring a dedicated modular changing room facility.
External openings
Module 1 forms part of the north and west elevations. Its north wall has a single glazed door positioned between two small windows, while its west end has one high-level, top-only window. Module 2 has two high-level, top-only windows on its exposed north wall.
Module 3 has two high-level, top-only windows on the north wall and one on the east end. Module 4 has one high-level, top-only window on its west end. No exposed-wall opening is specified for Module 5.
Module 6 has one high-level, top-only window on the east end and two on the south wall. Module 7 has two high-level, top-only windows on the south wall and one on the west end. Module 8 completes the stated openings with one high-level, top-only window on the east end and two on the south wall.
Anthracite external finish
The selected exposed outside walls are finished between the frame with Anthracite ARLINE AR16016 grooved plank cladding, using vertically arranged boards. This full-wall cladding is specified on the north and west walls of Module 1; the north walls of Modules 2 and 3; the east wall of Module 3; the west wall of Module 4; the east and south walls of Module 6; the south and west walls of Module 7; and the east and south walls of Module 8.
The building has a flat roof with an approximately 120mm steel-frame fascia. No additional fascia is selected. Final external details and finishes are confirmed by quotation.
Requested changing-room fit-out
A WC and shower have been requested, with their positions and the surrounding partitions to be confirmed in the final room layout. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels available as an optional selection. Shower rooms use wet-room PVC flooring.
Elsewhere, insulated sandwich panels are the included internal wall finish. Plaster can be applied outside bathroom walls when selected, while any other wall and floor finishes are determined by the agreed room arrangement. Illustrated fixtures or finishes are not guaranteed unless confirmed in the quotation.
Estimate and site considerations
The indicative configured estimate is £106,800 excluding VAT, or £128,160 including VAT, subject to quotation. Transport is priced separately according to postcode and site access. Offloading or cranage, groundworks and other site-specific works are also separate.
Siting remains subject to survey, including access, ground conditions and the requirements of the chosen location. The final specification, partition plan, fit-out and associated costs are established through the project quotation and the completed building configuration.
Full specification
8 P600 modules (single storey), grid layout, 17.7m x 6.6m footprint, approx 91.2 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m. Exterior: ARLINE AR16016 grooved plank applied to exposed walls between the frame in Anthracite. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia). Selected outside walls: Module 1 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 4 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 6 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 6 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 7 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 7 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 8 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 8 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards. Cladding prices are quote-only and must not be itemised in public copy. Module 1 P600 (ground floor) exposed walls — north (5.9m side): Small window + Glazed door (single) + Small window; west (2.2m end): Top-only window (high level). Module 2 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level) + Top-only window (high level). Module 3 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level) + Top-only window (high level); east (2.2m end): Top-only window (high level). Module 4 P600 (ground floor) exposed walls — west (2.2m end): Top-only window (high level). Module 5 P600 (ground floor) exposed walls — . Module 6 P600 (ground floor) exposed walls — east (2.2m end): Top-only window (high level); south (5.9m side): Top-only window (high level) + Top-only window (high level). Module 7 P600 (ground floor) exposed walls — south (5.9m side): Top-only window (high level) + Top-only window (high level); west (2.2m end): Top-only window (high level). Module 8 P600 (ground floor) exposed walls — east (2.2m end): Top-only window (high level); south (5.9m side): Top-only window (high level) + Top-only window (high level). Requested fit-out to confirm in the final layout: WC, shower. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.
Frequently asked questions
Make it yours
Change the module count, layout, windows, doors and finish — then get an instant estimate.
Get a price for 8-Module Single-Storey Changing Rooms with WC and Shower
Tell us what you need and we'll come back with pricing and lead times — usually within one working day.