Modular Changing Rooms
4-Module P600 Changing Room Configuration
This single-storey modular changing room configuration links four P600 modules in a 23.6m run. It is designed for football, rugby and cricket clubs requiring changing facilities with a WC and shower incorporated into the final layout.
£61,800ex VAT
£74,160 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.
Made to order. Build and delivery timing will be confirmed with your quotation.
Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.
Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.
- Modules
- 4
- Storeys
- 1
- Approx. usable internal area
- 45.6 m² before partitions
- External dimensions
- 23.6m x 2.2m footprint
Design highlights
- Four linked P600 modules in a single-storey run
- 23.6m x 2.2m external footprint
- Approximately 45.6m2 usable internal area before partitions
- ARLINE AR14514 fine-ribbed Venge cladding
- Dual-pitch apex roof
- Single glazed door with small and high-level windows
- WC and shower requested for the final layout
Four-module run layout
This configuration uses four steel-framed P600 modules linked end to end at ground-floor level. Each module measures 5.9m x 2.2m, creating an overall external footprint of 23.6m x 2.2m. The arrangement provides approximately 45.6m2 of usable internal area before partitions, based on a conservative per-module allowance. A connected open layout may provide more usable space, depending on the final partition plan.
Each module is approximately 2.40m high externally and has a 2.16m internal ceiling. Its approximate usable interior measures 5.7m x 2.0m. This long, single-storey format is suited to sports grounds where changing accommodation needs to follow the edge of a pitch, training area or existing clubhouse. It is configured for the Sport & Leisure sector as a modular changing room.
Windows and external access
The north and south elevations of all four modules each have three small windows. Module 1 also has a single glazed door on its south wall, positioned between two of that elevation’s small windows. At the outer ends of the run, Module 1 has a high-level, top-only window in its west wall, while Module 4 has a matching opening in its east wall.
This stored arrangement gives the building repeated window coverage along both long elevations, with a glazed external entrance in Module 1. The final internal partitions for changing areas, circulation and washroom facilities must be coordinated with these fixed external openings.
Venge cladding and apex roof
Selected exposed walls are finished with ARLINE AR14514 fine-ribbed cladding in Venge, applied between the frame with vertical boards. The selection covers the north and south walls of all four modules, the west end wall of Module 1 and the east end wall of Module 4. The building has a dual-pitch apex roof.
Cladding is priced as part of the project quotation and is not itemised in public-facing pricing. Final colours, junction details and visible finishes are confirmed by quotation rather than assumed from illustrations.
Requested WC and shower fit-out
A WC and shower are requested for incorporation into the final room layout. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels available as an optional selection. Shower rooms use wet-room PVC flooring. Where selected, plaster applies outside the bathroom walls.
Elsewhere, insulated sandwich panels are the included internal wall finish. Alternative wall and floor finishes depend on the final changing-room arrangement and the selections confirmed in the quotation. The stored configuration and room requirements can be reviewed through the building configurator, but final fixture positions, partitions and finishes remain subject to layout confirmation.
Price and site requirements
The indicative configured estimate is £61,800 excluding VAT, or £74,160 including VAT, subject to quotation. Transport is priced separately according to the delivery postcode and site access. Offloading or cranage, groundworks and other site-specific works are also separate.
Positioning and site requirements are subject to survey. Access, levels, foundations or supporting ground conditions, service connections and lifting requirements must be assessed for the intended location before the project details are finalised.
Full specification
4 P600 modules (single storey), run layout, 23.6m x 2.2m footprint, approx 45.6 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m. Exterior: ARLINE AR14514 fine-ribbed applied to exposed walls between the frame in Venge. Roof: dual-pitch (apex) roof. Selected outside walls: Module 1 North wall: Full-wall cladding, Venge, ARLINE AR14514 fine-ribbed, vertical boards; Module 1 South wall: Full-wall cladding, Venge, ARLINE AR14514 fine-ribbed, vertical boards; Module 1 West wall: Full-wall cladding, Venge, ARLINE AR14514 fine-ribbed, vertical boards; Module 2 North wall: Full-wall cladding, Venge, ARLINE AR14514 fine-ribbed, vertical boards; Module 2 South wall: Full-wall cladding, Venge, ARLINE AR14514 fine-ribbed, vertical boards; Module 3 North wall: Full-wall cladding, Venge, ARLINE AR14514 fine-ribbed, vertical boards; Module 3 South wall: Full-wall cladding, Venge, ARLINE AR14514 fine-ribbed, vertical boards; Module 4 North wall: Full-wall cladding, Venge, ARLINE AR14514 fine-ribbed, vertical boards; Module 4 East wall: Full-wall cladding, Venge, ARLINE AR14514 fine-ribbed, vertical boards; Module 4 South wall: Full-wall cladding, Venge, ARLINE AR14514 fine-ribbed, vertical boards. Cladding prices are quote-only and must not be itemised in public copy. Module 1 P600 (ground floor) exposed walls — north (5.9m side): Small window + Small window + Small window; south (5.9m side): Small window + Glazed door (single) + Small window; west (2.2m end): Top-only window (high level). Module 2 P600 (ground floor) exposed walls — north (5.9m side): Small window + Small window + Small window; south (5.9m side): Small window + Small window + Small window. Module 3 P600 (ground floor) exposed walls — north (5.9m side): Small window + Small window + Small window; south (5.9m side): Small window + Small window + Small window. Module 4 P600 (ground floor) exposed walls — north (5.9m side): Small window + Small window + Small window; east (2.2m end): Top-only window (high level); south (5.9m side): Small window + Small window + Small window. Requested fit-out to confirm in the final layout: WC, shower. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.
Frequently asked questions
Make it yours
Change the module count, layout, windows, doors and finish — then get an instant estimate.
Get a price for 4-Module P600 Changing Room Configuration
Tell us what you need and we'll come back with pricing and lead times — usually within one working day.