ADACON UK
    Two-storey grey modular site welfare unit positioned on an organised construction site.
    Six-module, two-storey P600 site welfare unit configured for construction-site canteen, drying and sanitary facilities.

    Site Welfare Units

    6-Module Two-Storey Site Welfare Unit

    This six-module P600 site welfare unit provides two storeys within an 11.8m x 4.4m external footprint. It suits construction sites requiring space for canteen, drying room, WC and shower facilities.

    £82,200ex VAT

    £98,640 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.

    Made to order. Build and delivery timing will be confirmed with your quotation.

    Call about this item
    PLACE ORDER

    Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.

    Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.

    Change the layout in the configurator
    Modules
    6
    Storeys
    2
    Approx. usable internal area
    68.4 m² before partitions
    External dimensions
    11.8m x 4.4m footprint

    Design highlights

    • Six P600 modules arranged over two storeys
    • 11.8m x 4.4m external footprint
    • Approximately 68.4m² usable internal area before partitions
    • Internal staircase between ground and first floors
    • Grey ARLINE AR16016 vertical grooved plank cladding
    • Single glazed entrance door with small and high-level windows
    • Kitchenette, WC and shower requested for the final layout

    Six-module, two-storey arrangement

    This configuration uses six steel-framed P600 modules arranged over two storeys, with three modules at ground level and three above. The building has an external footprint of 11.8m x 4.4m and an internal staircase connecting the floors. Each module measures 5.9m x 2.2m, is 2.40m high externally and has a 2.16m internal ceiling.

    Using a conservative allowance of approximately 5.7m x 2.0m per module, the configuration provides approximately 68.4m² of usable internal area before partitions. Connected open layouts may provide more usable space. The final division between canteen, drying, WC, shower and supporting spaces is confirmed through the room layout and quotation. Further context is available on the site welfare units page.

    Windows and external access

    On the ground floor, Module 1 has two small windows and a single glazed door on its north wall, plus two small windows on its west end. Module 2 has two high-level, top-only windows on both its north and south walls, with two small windows on its east end.

    Module 3 has two small windows on both its east and west ends, together with two high-level, top-only windows on its south wall. These ground-floor high-level openings support privacy in areas where the final welfare layout may require it.

    On the first floor, Module 4 has three small windows on its north wall and two on its west end. Module 5 has three small windows on each of its north and south walls, plus two on its east end. Module 6 has three small windows on its south wall and two on both its east and west ends.

    Grey grooved exterior and flat roof

    The selected exposed external walls are finished between the frame with Grey ARLINE AR16016 grooved plank cladding. The boards are arranged vertically across the specified north, south, east and west walls of the six modules. The roof is flat, with an approximately 120mm steel-frame fascia and no additional fascia selected.

    Requested welfare fit-out

    The requested fit-out comprises a kitchenette, WC and shower, subject to confirmation in the final room layout and quotation. This supports the intended construction-sector use as a site welfare unit for teams needing canteen, drying and sanitary facilities. The internal staircase is contained within the building and is not visible externally.

    Insulated sandwich panels are the included wall finish outside bathroom areas unless another finish is selected for the final layout. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels available as an option. Shower rooms use wet-room PVC flooring. Where plaster is selected, it applies outside the bathroom walls. Other internal finishes remain dependent on the agreed room arrangement.

    Estimate and site considerations

    The indicative configured estimate is £82,200 excluding VAT, or £98,640 including VAT, and remains subject to quotation. The stored arrangement and requested fit-out can be reviewed through the building configurator, with final fixture and finish details confirmed in the resulting quotation.

    Siting is subject to survey, including the proposed position, access and local site conditions. Transport is priced separately according to postcode and access. Offloading or cranage, groundworks and other site-specific works are also separate from the indicative configured estimate.

    Full specification

    6 P600 modules (two storeys), two-storey layout, 11.8m x 4.4m footprint, approx 68.4 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m.
    Exterior: ARLINE AR16016 grooved plank applied to exposed walls between the frame in Grey. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia).
    Selected outside walls: Module 1 North wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 1 West wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 2 North wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 2 East wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 2 South wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 3 East wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 3 South wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 3 West wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 4 North wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 4 West wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 5 North wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 5 East wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 5 South wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 6 East wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 6 South wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 6 West wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards. Cladding prices are quote-only and must not be itemised in public copy.
    Module 1 P600 (ground floor) exposed walls — north (5.9m side): Small window + Glazed door (single) + Small window; west (2.2m end): Small window + Small window.
    Module 2 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level) + Top-only window (high level); east (2.2m end): Small window + Small window; south (5.9m side): Top-only window (high level) + Top-only window (high level).
    Module 3 P600 (ground floor) exposed walls — east (2.2m end): Small window + Small window; south (5.9m side): Top-only window (high level) + Top-only window (high level); west (2.2m end): Small window + Small window.
    Module 4 P600 (first floor) exposed walls — north (5.9m side): Small window + Small window + Small window; west (2.2m end): Small window + Small window.
    Module 5 P600 (first floor) exposed walls — north (5.9m side): Small window + Small window + Small window; east (2.2m end): Small window + Small window; south (5.9m side): Small window + Small window + Small window.
    Module 6 P600 (first floor) exposed walls — east (2.2m end): Small window + Small window; south (5.9m side): Small window + Small window + Small window; west (2.2m end): Small window + Small window.
    Internal staircase between the two floors (not visible outside).
    Requested fit-out to confirm in the final layout: kitchenette, WC, shower. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.

    Frequently asked questions

    Make it yours

    Change the module count, layout, windows, doors and finish — then get an instant estimate.

    Get a price for 6-Module Two-Storey Site Welfare Unit

    Tell us what you need and we'll come back with pricing and lead times — usually within one working day.

    So we can call you back about your enquiry

    Enquiring about: 6-Module Two-Storey Site Welfare Unit

    No obligation. We reply within one working day.