ADACON UK
    Single-storey modular welfare building with Anthracite grooved cladding at a construction site
    Four-module P600 site welfare unit configured for construction-site canteen, drying room, WC and shower use.

    Site Welfare Units

    4-Module Site Welfare Unit with Canteen, WC and Shower

    This single-storey site welfare unit combines four P600 modules in a 23.6m run, with a kitchenette, WC and shower requested for the final layout. It suits construction sites requiring canteen, drying room and WC facilities in one connected building.

    £55,200ex VAT

    £66,240 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.

    Made to order. Build and delivery timing will be confirmed with your quotation.

    Call about this item
    PLACE ORDER

    Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.

    Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.

    Change the layout in the configurator
    Modules
    4
    Storeys
    1
    Approx. usable internal area
    45.6 m² before partitions
    External dimensions
    23.6m x 2.2m footprint

    Design highlights

    • Four connected P600 modules in a single-storey run
    • 23.6m x 2.2m external footprint
    • Approximately 45.6 m2 usable internal area before partitions
    • Double glazed entrance door and 27 small windows
    • Anthracite ARLINE AR16016 vertical grooved plank cladding
    • Kitchenette, WC and shower requested for the final layout
    • Flat roof with approximately 120mm steel-frame fascia

    Four connected P600 modules

    This configuration places four 5.9m x 2.2m P600 steel-framed modules in a single-storey run. The completed building has an external footprint of 23.6m x 2.2m and provides approximately 45.6 m2 of usable internal area before partitions, based on a conservative per-module allowance. Connected open layouts may provide more usable space. Each module is approximately 2.40m high externally, with a 2.16m internal ceiling and an approximate usable interior of 5.7m x 2.0m.

    The connected arrangement is intended to support a practical mix of canteen, drying room and WC accommodation. The positions and sizes of the requested rooms remain subject to confirmation through the final plan.

    Windows and external access

    Module 1 has three small windows on its north elevation. Its south elevation has a double glazed door positioned between two small windows, while its exposed west end has two small windows. Modules 2 and 3 each have three small windows on the north elevation and three on the south elevation.

    Module 4 continues the same pattern with three small windows on its north elevation and three on its south elevation. Its exposed east end contains a further two small windows. These openings are specific to this stored configuration and provide glazing along both long elevations as well as the two exposed ends.

    Anthracite grooved exterior

    All selected exposed walls are finished between the frame with Anthracite ARLINE AR16016 grooved plank cladding. The boards run vertically across the north and south elevations of all four modules, the west end of Module 1 and the east end of Module 4. The building has a flat roof with an approximately 120mm steel-frame fascia and no additional fascia.

    Requested welfare fit-out

    The requested internal fit-out includes a kitchenette, WC and shower, with the final arrangement to be confirmed against the room plan. This supports the intended use as a site welfare unit for construction teams requiring eating, changing or drying, washing and toilet facilities.

    Insulated sandwich panels are the included wall finish outside the bathroom areas. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels available as an option. Shower rooms use wet-room PVC flooring. Plaster can be selected outside bathroom walls, while other finishes depend on the final room layout and quotation. Illustrated fixtures and finishes should not be treated as confirmed until the quotation is agreed.

    Estimate, transport and siting

    The indicative configured estimate is £55,200 excluding VAT or £66,240 including VAT, subject to quotation. Transport is priced separately according to the destination postcode and site access. Offloading or cranage, groundworks and other site-specific works are also separate.

    Final siting is subject to a site survey covering access, levels, ground conditions and the requirements for positioning the full 23.6m run. Layout details, internal finishes and requested welfare facilities can then be confirmed through the building configurator and final quotation.

    Full specification

    4 P600 modules (single storey), run layout, 23.6m x 2.2m footprint, approx 45.6 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m.
    Exterior: ARLINE AR16016 grooved plank applied to exposed walls between the frame in Anthracite. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia).
    Selected outside walls: Module 1 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 4 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 4 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 4 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards. Cladding prices are quote-only and must not be itemised in public copy.
    Module 1 P600 (ground floor) exposed walls — north (5.9m side): Small window + Small window + Small window; south (5.9m side): Small window + Glazed door (double) + Small window; west (2.2m end): Small window + Small window.
    Module 2 P600 (ground floor) exposed walls — north (5.9m side): Small window + Small window + Small window; south (5.9m side): Small window + Small window + Small window.
    Module 3 P600 (ground floor) exposed walls — north (5.9m side): Small window + Small window + Small window; south (5.9m side): Small window + Small window + Small window.
    Module 4 P600 (ground floor) exposed walls — north (5.9m side): Small window + Small window + Small window; east (2.2m end): Small window + Small window; south (5.9m side): Small window + Small window + Small window.
    Requested fit-out to confirm in the final layout: kitchenette, WC, shower. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.

    Frequently asked questions

    Make it yours

    Change the module count, layout, windows, doors and finish — then get an instant estimate.

    Get a price for 4-Module Site Welfare Unit with Canteen, WC and Shower

    Tell us what you need and we'll come back with pricing and lead times — usually within one working day.

    So we can call you back about your enquiry

    Enquiring about: 4-Module Site Welfare Unit with Canteen, WC and Shower

    No obligation. We reply within one working day.