Modular Shower Blocks
4-Module Shower Block Configuration
This single-storey modular shower block links four P600 modules in a straight run, with a WC and shower requested for the final layout. It suits construction sites, campsites and sports clubs requiring a long, practical washroom building.
£55,200ex VAT
£66,240 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.
Made to order. Build and delivery timing will be confirmed with your quotation.
Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.
Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.
- Modules
- 4
- Storeys
- 1
- Approx. usable internal area
- 45.6 m² before partitions
- External dimensions
- 23.6m x 2.2m footprint
Design highlights
- Four linked P600 modules in a single-storey run
- 23.6m x 2.2m external footprint
- Approximately 45.6m² usable internal area before partitions
- Grey ARLINE AR16016 vertical grooved plank cladding
- Glazed double-door entrance with high-level and small windows
- WC and shower requested for the final layout
- Flat roof with approximately 120mm steel-frame fascia
Four-module run layout
This configuration uses four steel-framed P600 modules linked in a single-storey run. Each module measures 5.9m x 2.2m, creating an overall external footprint of 23.6m x 2.2m. The configuration provides approximately 45.6m² of usable internal area before partitions, based on a conservative per-module allowance; a connected open layout may provide more space. Each module is approximately 2.40m high externally, with a 2.16m internal ceiling and an approximate usable interior of 5.7m x 2.0m.
Windows and entrance
Module 1 forms the western end of the run. Its north wall has two high-level, top-only windows, while the south wall combines a small window, a glazed double door and a second small window. A further high-level, top-only window is positioned on the exposed west end wall.
Modules 2 and 3 each have two high-level, top-only windows on both their north and south walls. Module 4 follows the same arrangement on its north and south walls, with an additional high-level, top-only window on the exposed east end. These openings form part of this stored configuration, while the relationship between the requested facilities, partitions and openings is confirmed through the final quoted layout.
Grey grooved exterior
All exposed outside walls are specified with Grey ARLINE AR16016 grooved plank cladding applied between the frame. The boards run vertically across the north and south elevations, as well as the exposed west wall of Module 1 and east wall of Module 4. Cladding costs are quote-only and are not itemised publicly. Above, the building has a flat roof with an approximately 120mm steel-frame fascia and no additional fascia.
Requested washroom fit-out
A WC and shower have been requested, with their positions and the final partition arrangement still to be confirmed. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels available as an optional selection. Shower rooms use wet-room PVC flooring. Where selected, plaster applies outside bathroom walls. Elsewhere, insulated sandwich panels are the included internal wall finish, with any alternative finishes chosen to suit the final room layout and confirmed by quotation.
Use, pricing and siting
Designed for the Construction sector, this configuration can serve as a modular shower block for construction sites, campsites or sports clubs. The indicative configured estimate is £55,200 ex VAT or £66,240 inc VAT, subject to quotation and confirmation of the final fit-out and finishes.
Transport is priced separately according to postcode and site access. Offloading or cranage, groundworks and other site-specific works are also separate. Final siting is subject to a site survey, including checks on access, positioning and the works required before the configuration is confirmed through the building configurator.
Full specification
4 P600 modules (single storey), run layout, 23.6m x 2.2m footprint, approx 45.6 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m. Exterior: ARLINE AR16016 grooved plank applied to exposed walls between the frame in Grey. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia). Selected outside walls: Module 1 North wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 1 South wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 1 West wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 2 North wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 2 South wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 3 North wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 3 South wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 4 North wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 4 East wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards; Module 4 South wall: Full-wall cladding, Grey, ARLINE AR16016 grooved plank, vertical boards. Cladding prices are quote-only and must not be itemised in public copy. Module 1 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level) + Top-only window (high level); south (5.9m side): Small window + Glazed door (double) + Small window; west (2.2m end): Top-only window (high level). Module 2 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level) + Top-only window (high level); south (5.9m side): Top-only window (high level) + Top-only window (high level). Module 3 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level) + Top-only window (high level); south (5.9m side): Top-only window (high level) + Top-only window (high level). Module 4 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level) + Top-only window (high level); east (2.2m end): Top-only window (high level); south (5.9m side): Top-only window (high level) + Top-only window (high level). Requested fit-out to confirm in the final layout: WC, shower. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.
Frequently asked questions
Make it yours
Change the module count, layout, windows, doors and finish — then get an instant estimate.
Get a price for 4-Module Shower Block Configuration
Tell us what you need and we'll come back with pricing and lead times — usually within one working day.