
Toilet & Shower Blocks
4-Module P600 Toilet and Shower Block
This single-storey toilet and shower block links four P600 modules in a wide 5.9m x 8.8m configuration. It suits large construction sites, holiday parks and campsites requiring dedicated WC and shower facilities.
£54,000ex VAT
£64,800 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.
Made to order. Build and delivery timing will be confirmed with your quotation.
Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.
Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.
- Modules
- 4
- Storeys
- 1
- Approx. usable internal area
- 45.6 m² before partitions
- External dimensions
- 5.9m x 8.8m footprint
Design highlights
- Four linked P600 modules in a single-storey layout
- 5.9m x 8.8m external footprint
- Approximately 45.6 m² usable internal area before partitions
- Double-door glazed entrance with small side windows
- High-level, top-only windows on exposed ends
- Anthracite ARLINE AR16016 vertical grooved cladding
- Requested WC and shower fit-out
Four-module wide layout
This stored configuration uses four linked P600 steel-framed modules arranged side by side on one level. Together, they create an external footprint of 5.9m x 8.8m and approximately 45.6 m² of usable internal area before partitions, based on a conservative per-module allowance. Connected open layouts may provide more usable space, depending on the final partition plan.
Each module measures 5.9m x 2.2m externally and is 2.40m high, with an internal ceiling height of 2.16m. The approximate usable interior of each module is 5.7m x 2.0m. The final WC, shower and circulation arrangement remains subject to layout confirmation and quotation.
Doors and windows
The exposed elevations use a defined combination of glazed access and high-level windows:
- Module 1 has two small windows and a double-door glazed entrance on its north wall.
- Module 1 also has one high-level, top-only window on each of its east and west ends.
- Modules 2 and 3 each have one high-level, top-only window on both their east and west ends.
- Module 4 has high-level, top-only windows on its east end, west end and south wall.
This arrangement places the main glazed entrance on the north-facing side of Module 1, while the remaining exposed ends and the south wall of Module 4 use high-level openings.
Anthracite grooved external finish
Every exposed wall in this configuration is selected with full-wall ARLINE AR16016 grooved plank cladding. The Anthracite vertical boards are applied between the frame across the north, east and west walls of Module 1; the east and west ends of Modules 2 and 3; and the east, south and west walls of Module 4. Final fixture and finish details are confirmed by quotation.
The building has a flat roof with approximately 120mm steel-frame fascia. No additional fascia is included in the stored design.
Requested WC and shower fit-out
The requested fit-out includes WC and shower provision, with the exact sanitary arrangement and room divisions to be confirmed in the final layout. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels available as an optional selection. Shower rooms use wet-room PVC flooring.
Elsewhere, insulated sandwich panels are the included internal wall finish. Plaster can be applied outside bathroom walls when selected, while any other finishes are chosen to suit the confirmed room layout. Further information on this application is available under toilet and shower blocks.
Estimate, transport and siting
The indicative configured estimate is £54,000 ex VAT, or £64,800 including VAT, subject to quotation. Transport is priced separately according to the delivery postcode and site access. Offloading or cranage, groundworks and other site-specific works are also separate.
Siting is subject to survey, including confirmation of access, ground conditions and the works required for the location. The stored arrangement can be reviewed through the P600 configurator, but the final layout, fixtures and finishes are those recorded in the accepted quotation.
Full specification
4 P600 modules (single storey), wide layout, 5.9m x 8.8m footprint, approx 45.6 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m. Exterior: ARLINE AR16016 grooved plank applied to exposed walls between the frame in Anthracite. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia). Selected outside walls: Module 1 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 4 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 4 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 4 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards. Cladding prices are quote-only and must not be itemised in public copy. Module 1 P600 (ground floor) exposed walls — north (5.9m side): Small window + Glazed door (double) + Small window; east (2.2m end): Top-only window (high level); west (2.2m end): Top-only window (high level). Module 2 P600 (ground floor) exposed walls — east (2.2m end): Top-only window (high level); west (2.2m end): Top-only window (high level). Module 3 P600 (ground floor) exposed walls — east (2.2m end): Top-only window (high level); west (2.2m end): Top-only window (high level). Module 4 P600 (ground floor) exposed walls — east (2.2m end): Top-only window (high level); south (5.9m side): Top-only window (high level); west (2.2m end): Top-only window (high level). Requested fit-out to confirm in the final layout: WC, shower. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.
Frequently asked questions
Make it yours
Change the module count, layout, windows, doors and finish — then get an instant estimate.
Get a price for 4-Module P600 Toilet and Shower Block
Tell us what you need and we'll come back with pricing and lead times — usually within one working day.