ADACON UK
    Single-storey anthracite-clad modular site welfare unit on a construction site
    Three-module P600 site welfare unit configured for construction-sector welfare facilities.

    Site Welfare Units

    3-Module Site Welfare Unit with WC and Shower

    This single-storey site welfare unit combines three P600 modules in a wide 5.9m x 6.6m configuration, with a WC and shower requested for the final layout. It suits construction sites planning welfare space for facilities such as a canteen, drying room and WC.

    £40,700ex VAT

    £48,840 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.

    Made to order. Build and delivery timing will be confirmed with your quotation.

    Call about this item
    PLACE ORDER

    Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.

    Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.

    Change the layout in the configurator
    Modules
    3
    Storeys
    1
    Approx. usable internal area
    34.2 m² before partitions
    External dimensions
    5.9m x 6.6m footprint

    Design highlights

    • Three P600 modules in a single-storey wide layout
    • 5.9m x 6.6m external footprint
    • Approximately 34.2m² usable internal area before partitions
    • Single glazed entrance door with small and high-level windows
    • Anthracite vertical ARLINE AR16016 grooved plank cladding
    • WC and shower requested for the final layout
    • Flat roof with approximately 120mm steel-frame fascia

    Wide three-module welfare configuration

    This construction-sector welfare building places three steel-framed P600 modules side by side in a single-storey, wide layout. The external footprint is 5.9m x 6.6m, and each module measures 5.9m x 2.2m externally. The configuration is intended for construction sites requiring practical welfare accommodation and can be planned around needs such as canteen, drying and WC facilities. Related configurations can be viewed under site welfare units.

    The indicative configured estimate is £40,700 excluding VAT, or £48,840 including VAT. This is subject to quotation and confirmation of the final internal layout, finishes, access requirements and site-specific scope.

    Internal dimensions and usable space

    Each module is 2.40m high externally and has a 2.16m internal ceiling. Its approximate usable interior measures 5.7m x 2.0m. Across the three modules, the conservative usable internal area is approximately 34.2m² before partitions. A connected open layout may provide more usable space, but the final figure depends on the confirmed arrangement.

    The modules are linked across their long sides to form the 6.6m-wide footprint. Internal partitions and room positions are to be confirmed when the requested WC and shower are incorporated into the final plan. The stored configuration does not fix separate canteen or drying-room zones.

    Windows and entrance

    On Module 1, the exposed north wall has a single glazed door positioned with one small window on either side. Its east and west end walls each have two small windows. Module 2 has two small windows on each exposed end wall. Module 3 also has two small windows on both exposed end walls, while its south wall has two high-level, top-only windows. These openings are specific to this three-module arrangement.

    Anthracite external finish

    The selected exposed walls use Anthracite ARLINE AR16016 grooved plank cladding, with the boards arranged vertically between the frame. This finish is applied to the north, east and west walls of Module 1; the east and west walls of Module 2; and the east, south and west walls of Module 3. Cladding costs are quote-only and are not itemised publicly. The building has a flat roof with an approximately 120mm steel-frame fascia and no additional fascia.

    Requested WC and shower fit-out

    A WC and shower have been requested, subject to confirmation within the final room layout. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels available as an optional selection. Shower rooms use wet-room PVC flooring. Where selected, plaster applies to the outside faces of bathroom walls. Elsewhere, insulated sandwich panels are the included internal wall finish, while any alternative finishes are chosen to suit the confirmed room arrangement.

    Quotation and site requirements

    The final specification can be reviewed through the building configurator. Siting remains subject to survey and confirmation of the proposed location, postcode and access. Transport is priced according to postcode and access conditions. Offloading or cranage, groundworks and other site-specific works are separate from the indicative configured estimate. Fixtures, finishes and room details shown in supporting illustrations remain subject to the final quotation.

    Full specification

    3 P600 modules (single storey), wide layout, 5.9m x 6.6m footprint, approx 34.2 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m.
    Exterior: ARLINE AR16016 grooved plank applied to exposed walls between the frame in Anthracite. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia).
    Selected outside walls: Module 1 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards. Cladding prices are quote-only and must not be itemised in public copy.
    Module 1 P600 (ground floor) exposed walls — north (5.9m side): Small window + Glazed door (single) + Small window; east (2.2m end): Small window + Small window; west (2.2m end): Small window + Small window.
    Module 2 P600 (ground floor) exposed walls — east (2.2m end): Small window + Small window; west (2.2m end): Small window + Small window.
    Module 3 P600 (ground floor) exposed walls — east (2.2m end): Small window + Small window; south (5.9m side): Top-only window (high level) + Top-only window (high level); west (2.2m end): Small window + Small window.
    Requested fit-out to confirm in the final layout: WC, shower. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.

    Frequently asked questions

    Make it yours

    Change the module count, layout, windows, doors and finish — then get an instant estimate.

    Get a price for 3-Module Site Welfare Unit with WC and Shower

    Tell us what you need and we'll come back with pricing and lead times — usually within one working day.

    So we can call you back about your enquiry

    Enquiring about: 3-Module Site Welfare Unit with WC and Shower

    No obligation. We reply within one working day.