
Toilet & Shower Blocks
3-Module P600 Toilet and Shower Block
This single-storey P600 toilet and shower block combines three modules in a 17.7m linear run. It suits holiday parks, campsites and large construction sites requiring dedicated WC and shower facilities.
£41,500ex VAT
£49,800 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.
Made to order. Build and delivery timing will be confirmed with your quotation.
Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.
Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.
- Modules
- 3
- Storeys
- 1
- Approx. usable internal area
- 34.2 m² before partitions
- External dimensions
- 17.7m x 2.2m footprint
Design highlights
- Three P600 modules in a single-storey linear run
- 17.7m x 2.2m external footprint
- Approx. 34.2m² usable internal area before partitions
- Requested WC and shower fit-out
- Anthracite ARLINE AR16016 vertical grooved-plank cladding
- High-level windows with a single glazed entrance door
- Flat roof with approximately 120mm steel-frame fascia
Three-module linear layout
This stored configuration uses three P600 steel-framed modules linked in a single-storey run. Its external footprint is 17.7m x 2.2m, with an approximate usable internal area of 34.2m² before partitions. This is based on a conservative per-module allowance; a connected open layout may provide more usable space.
Each module measures 5.9m x 2.2m externally and has an external height of 2.40m. The approximate usable interior of each module is 5.7m x 2.0m, with a 2.16m internal ceiling. The final partition arrangement will reflect the confirmed WC and shower layout for this toilet and shower block.
Windows and external access
Module 1 has two high-level top-only windows on its north wall. Its south wall has two small windows and a single glazed door, while the exposed west end has one high-level top-only window.
Module 2 has two high-level top-only windows on its north wall and two on its south wall. Module 3 repeats this arrangement on its north and south walls, with a further high-level top-only window on the exposed east end. These specified openings provide the stored design with daylight, privacy and one external entrance.
Anthracite grooved-plank exterior
ARLINE AR16016 grooved-plank cladding in Anthracite is applied between the frame on the selected exposed walls. The vertical boards cover the north and south walls of all three modules, together with Module 1’s west end and Module 3’s east end.
The building has a flat roof with an approximately 120mm steel-frame fascia and no additional fascia. Cladding is priced as part of the quotation and is not separately itemised in public pricing.
WC and shower fit-out
The requested fit-out includes a WC and shower, with positions and room divisions to be confirmed in the final layout. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, while hygienic panels are an optional selection. Shower rooms use wet-room PVC flooring.
Elsewhere, insulated sandwich panels are the included internal wall finish. Plaster can be selected outside the bathroom walls, and other finishes are chosen to suit the final room layout. Illustrated fixtures and finishes are indicative; the final specification is confirmed by quotation and recorded through the building configuration.
Price, transport and siting
The indicative configured estimate is £41,500 excluding VAT, or £49,800 including VAT, subject to quotation. Transport is priced according to the delivery postcode and site access. Offloading or cranage, groundworks and other site-specific works are separate.
Final siting is subject to a site survey, including access, positioning and relevant site conditions. The quotation will confirm the agreed layout, fit-out, finishes and project-specific requirements.
Full specification
3 P600 modules (single storey), run layout, 17.7m x 2.2m footprint, approx 34.2 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m. Exterior: ARLINE AR16016 grooved plank applied to exposed walls between the frame in Anthracite. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia). Selected outside walls: Module 1 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards. Cladding prices are quote-only and must not be itemised in public copy. Module 1 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level) + Top-only window (high level); south (5.9m side): Small window + Glazed door (single) + Small window; west (2.2m end): Top-only window (high level). Module 2 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level) + Top-only window (high level); south (5.9m side): Top-only window (high level) + Top-only window (high level). Module 3 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level) + Top-only window (high level); east (2.2m end): Top-only window (high level); south (5.9m side): Top-only window (high level) + Top-only window (high level). Requested fit-out to confirm in the final layout: WC, shower. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.
Frequently asked questions
Make it yours
Change the module count, layout, windows, doors and finish — then get an instant estimate.
Get a price for 3-Module P600 Toilet and Shower Block
Tell us what you need and we'll come back with pricing and lead times — usually within one working day.