Modular Toilet Blocks
3-Module P600 Modular Toilet Block
This single-storey modular toilet block combines three P600 modules in a 17.7m run, with a WC fit-out requested for the final layout. It suits construction sites, events and sports grounds requiring permanent WC provision.
£41,500ex VAT
£49,800 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.
Made to order. Build and delivery timing will be confirmed with your quotation.
Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.
Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.
- Modules
- 3
- Storeys
- 1
- Approx. usable internal area
- 34.2 m² before partitions
- External dimensions
- 17.7m x 2.2m footprint
Design highlights
- Three P600 modules in a single-storey run
- 17.7m x 2.2m external footprint
- Approximately 34.2m² usable internal area before partitions
- Requested WC fit-out for the final room layout
- Anthracite ARLINE AR16016 vertical grooved cladding
- High-level top-only windows across all three modules
- Pair of glazed entrance doors with two small windows
Three-module run layout
This configuration uses three P600 steel-framed modules arranged as a straight, single-storey run. Each module measures 5.9m x 2.2m, creating an overall external footprint of 17.7m x 2.2m. The building is intended as a modular toilet block for permanent WC provision at construction sites, events and sports grounds.
Each module is 2.40m high externally and has an internal ceiling height of 2.16m. The approximate usable interior of each module is 5.7m x 2.0m. Across the three modules, the configuration provides approximately 34.2m² of usable internal area before partitions, based on a conservative per-module allowance. A connected open layout may provide more usable space, depending on the final room arrangement.
Windows and entrance
The first module has a high-level, top-only window on its north wall and another on the exposed west end. Its south wall contains a pair of glazed doors, with one small window on each side. The second module has one high-level, top-only window on both its north and south walls.
The third module also has high-level, top-only windows on its north and south walls, plus a further high-level, top-only window on the exposed east end. These are the stored openings for this configuration; their relationship to internal partitions will be confirmed when the WC layout is finalised.
Anthracite external finish
All exposed wall areas are specified with Anthracite ARLINE AR16016 grooved plank cladding, fitted between the structural frame with the boards running vertically. This applies to the north and south walls of all three modules, the west end of Module 1 and the east end of Module 3. The building has a flat roof with an approximately 120mm steel-frame fascia and no additional fascia.
Requested WC fit-out
A WC is requested, but the final arrangement of cubicles, sanitary areas and partitions remains subject to the confirmed room layout and quotation. Bathroom walls use 40mm waterproof insulated sandwich panels as standard. Hygienic wall panels are available as an optional selection. Where a shower room is selected, wet-room PVC flooring is used; this stored design does not confirm a shower room.
Elsewhere, insulated sandwich panels are the included internal wall finish. Plaster can be applied outside bathroom walls when selected, while other finishes are chosen to suit the final room layout. Fixtures, finishes and room details shown in supporting imagery are not guaranteed unless they are confirmed in the quotation.
Price, transport and siting
The indicative configured estimate is £41,500 excluding VAT, or £49,800 including VAT, subject to quotation. Transport is priced separately according to postcode and site access. Offloading or cranage, groundworks and other site-specific works are also separate. Final siting is subject to a site survey covering access, ground conditions and the requirements of the completed scheme. Configuration details can be reviewed through the building configurator before quotation.
Full specification
3 P600 modules (single storey), run layout, 17.7m x 2.2m footprint, approx 34.2 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m. Exterior: ARLINE AR16016 grooved plank applied to exposed walls between the frame in Anthracite. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia). Selected outside walls: Module 1 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 3 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards. Cladding prices are quote-only and must not be itemised in public copy. Module 1 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level); south (5.9m side): Small window + Glazed door (double) + Small window; west (2.2m end): Top-only window (high level). Module 2 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level); south (5.9m side): Top-only window (high level). Module 3 P600 (ground floor) exposed walls — north (5.9m side): Top-only window (high level); east (2.2m end): Top-only window (high level); south (5.9m side): Top-only window (high level). Requested fit-out to confirm in the final layout: WC. Bathroom walls use 40mm waterproof insulated sandwich panels as standard, with hygienic panels optional; shower rooms use wet-room PVC flooring. Plaster applies outside bathroom walls when selected. Elsewhere insulated sandwich panels are the included wall finish; other finishes are selected for the final room layout.
Frequently asked questions
Make it yours
Change the module count, layout, windows, doors and finish — then get an instant estimate.
Get a price for 3-Module P600 Modular Toilet Block
Tell us what you need and we'll come back with pricing and lead times — usually within one working day.