ADACON UK
    Anthracite-clad modular secure storage unit on a construction compound
    Two-module P600 secure storage unit configured for contractors, tradespeople and construction businesses.

    Secure Storage Units

    2-Module Secure Storage Unit with Roller Shutters

    This single-storey secure storage unit combines two P600 modules in an 11.8m run with multiple roller-shutter access points. It suits contractors, tradespeople and businesses requiring practical lock-up space for construction equipment, tools or materials.

    £27,800ex VAT

    £33,360 inc VAT · indicative configured estimate, subject to quotation. Transport depends on postcode and access; offloading, groundworks and site-specific works are separate.

    Made to order. Build and delivery timing will be confirmed with your quotation.

    Call about this item
    PLACE ORDER

    Order the standard specification online. We'll confirm delivery, access and final order details before accepting your order and issuing your invoice.

    Built to order in approx. 7–8 weeks, then delivery typically within 1–2 weeks. Delivery is priced by postcode and confirmed with your quote.

    Change the layout in the configurator
    Modules
    2
    Storeys
    1
    Approx. usable internal area
    22.8 m² before partitions
    External dimensions
    11.8m x 2.2m footprint

    Design highlights

    • Two P600 modules in a single-storey run
    • 11.8m x 2.2m external footprint
    • Approximately 22.8m2 usable internal area before partitions
    • Seven full-size roller shutters
    • Single glazed door and three specified windows
    • Anthracite ARLINE AR16016 vertical grooved cladding
    • White lightly ribbed insulated internal wall panels

    Two-module run layout

    This secure storage configuration uses two P600 steel-framed modules arranged as a single-storey run. Its external footprint is 11.8m x 2.2m, providing approximately 22.8m2 of usable internal area before partitions. This figure uses a conservative allowance for each module; a connected open layout may provide more usable space where retained in the final room design.

    Each module measures 5.9m x 2.2m externally and has an external height of 2.40m. The approximate usable interior of each module is 5.7m x 2.0m, with a 2.16m internal ceiling. The long, narrow format supports organised storage zones while keeping equipment accessible from several points around the building. It is intended for contractors, tradespeople and other businesses operating in the construction sector.

    External access and windows

    Module 1 has two full-size roller shutters on its north-facing 5.9m side. Its south-facing side has one full-size roller shutter, one single glazed door and one small window. A high-level, top-only window is positioned in the exposed west end wall.

    Module 2 also provides extensive roller-shutter access. Its north-facing 5.9m side has two full-size roller shutters, while its south-facing side has a further two full-size roller shutters. The exposed east end wall contains one high-level, top-only window.

    This arrangement gives the complete configuration seven full-size roller shutters, alongside the glazed personnel door and three specified windows. The distribution of openings is particular to this stored design and supports access to different parts of the run without adding an unconfirmed internal room arrangement.

    Anthracite external finish

    The selected exposed outside walls are finished with Anthracite ARLINE AR16016 grooved plank cladding, installed as vertical boards between the frame. On Module 1, this finish covers the north, south and west walls. On Module 2, it covers the north, east and south walls. Cladding is subject to the final quotation and is not separately itemised in this product description.

    The building has a flat roof with an approximately 120mm steel-frame fascia. No additional fascia has been selected for this configuration, keeping the roof edge aligned with the module frame.

    Internal specification

    No wet fit-out has been requested. The included internal wall specification uses white, lightly ribbed insulated sandwich panels. Plasterboard and hygienic wall panels remain optional alternatives where appropriate to the final use and quotation.

    Flooring has not been fixed in the stored design and is selected to suit the final room layout. Any partitions, room divisions and associated finishes should therefore be confirmed when the specification is reviewed through the building configurator. Illustrated finishes or fixtures should not be treated as guaranteed; final details are established in the quotation.

    Price, transport and siting

    The indicative configured estimate is £27,800 ex VAT, or £33,360 including VAT, subject to quotation. Transport is priced separately according to the delivery postcode and site access. Offloading or cranage, groundworks and other site-specific works are also separate.

    Final siting is subject to survey and confirmation of access, ground conditions and the requirements of the intended location. The quotation will establish the final specification, selected finishes and costs for the completed project.

    Full specification

    2 P600 modules (single storey), run layout, 11.8m x 2.2m footprint, approx 22.8 m2 usable internal area before partitions (conservative per-module allowance; connected open layouts may provide more space). Each module is 2.40m externally with a 2.16m internal ceiling; its approximate usable interior is 5.7m x 2.0m.
    Exterior: ARLINE AR16016 grooved plank applied to exposed walls between the frame in Anthracite. Roof: flat roof with approximately 120mm steel-frame fascia (no extra fascia).
    Selected outside walls: Module 1 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 1 West wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 North wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 East wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards; Module 2 South wall: Full-wall cladding, Anthracite, ARLINE AR16016 grooved plank, vertical boards. Cladding prices are quote-only and must not be itemised in public copy.
    Module 1 P600 (ground floor) exposed walls — north (5.9m side): Roller shutter (full size) + Roller shutter (full size); south (5.9m side): Roller shutter (full size) + Glazed door (single) + Small window; west (2.2m end): Top-only window (high level).
    Module 2 P600 (ground floor) exposed walls — north (5.9m side): Roller shutter (full size) + Roller shutter (full size); east (2.2m end): Top-only window (high level); south (5.9m side): Roller shutter (full size) + Roller shutter (full size).
    No wet fit-out requested. Included internal walls are white lightly ribbed insulated sandwich panels; plasterboard and hygienic panels are optional. Flooring is selected for the final room layout.

    Frequently asked questions

    Make it yours

    Change the module count, layout, windows, doors and finish — then get an instant estimate.

    Get a price for 2-Module Secure Storage Unit with Roller Shutters

    Tell us what you need and we'll come back with pricing and lead times — usually within one working day.

    So we can call you back about your enquiry

    Enquiring about: 2-Module Secure Storage Unit with Roller Shutters

    No obligation. We reply within one working day.